Maintaining contamination-free material transfer is essential for every cleanroom environment. Equipment such as Static Pass Boxes, Dynamic Pass Boxes, and Hatch Pass Troughs play an important role in ensuring safe and controlled movement of materials between different clean zones.
At Brinda Pharma Technologies Private Limited, we manufacture high-precision cleanroom transfer systems designed to meet GMP, ISO, and regulatory requirements. This guide provides a clear, step-by-step process to help you achieve proper installation and long-term performance.
| Step | Description |
|---|---|
| 1. Pre-Installation Checklist | Confirm wall location & mounting height – Verify cleanroom classification (ISO 5, 7, 8) – Prepare electrical points (for Dynamic Pass Box) Check wall load-bearing capacity – Ensure space for door opening & maintenance |
| 2. Tools Required | Drill machine – Anchors & fasteners – Leveling tools – Electrical wiring tools – Cleanroom-grade silicone sealant – PPE safety gear |
| 3. Wall Cutout Preparation | Mark exact cutout dimensions – Ensure proper alignment & leveling – Remove dust, debris & loose particles – Smoothen and clean the surface |
| 4A. Installation (Static Pass Box) | Insert into wall cutout – Align and level – Secure with bolts/anchors – Seal edges with cleanroom silicone |
| 4B. Installation (Dynamic Pass Box) | Position in cutout – Connect electrical supply – Verify blower & HEPA filter seating – Seal all joints for airtight fit |
| 4C. Installation (Hatch Pass Trough) | Insert horizontally into cutout – Level and align – Fasten securely – Apply silicone sealant for airtight installation |
| 5. Post-Installation Testing | Static & Hatch: Door alignment, gasket sealing, interlocking test Dynamic: Airflow test, HEPA integrity test (DOP/PAO), noise/vibration check, particle count |
| 6. Final Validation | Installation documentation – HEPA filter reports (Dynamic) – Airflow & interlock certificates – Maintenance schedule preparation |
| Activity | Recommendation |
|---|---|
| Cleaning | Use approved cleanroom disinfectants regularly. |
| Interlock Check | Test monthly for smooth operation. |
| HEPA Filter Replacement | Replace as per schedule or pressure drop readings. |
| Avoid Overloading | Do not place oversized or heavy materials beyond capacity. |
| Preventive Maintenance | Schedule service with Brinda Pharma Technologies Pvt. Ltd. |
Benefits:
Ensure your cleanroom operates at maximum efficiency with professional installation services from Brinda Pharma Technologies Private Limited.